Whirlpool Dryer Not Heating: 29 of 55 Were the Heating Element
A Whirlpool dryer that is not heating usually still does everything else. The drum turns, the air moves, the timer counts down, and the clothes come out as wet as they went in. There is rarely a code for it. Of the fifty-five no-heat and won’t-dry jobs below, only one owner saw anything on the display (E01). I will get to what that one turned out to be.
These are my last fifty-five Whirlpool-built dryers that came in as not heating or not drying. Most were electric, some were gas, and a few wore a Maytag or Estate badge. Here is what they actually were.
What no heat really was, fifty-five times
- Twenty-nine of fifty-five — the heating element had failed and was replaced. On two of those I also replaced the high limit thermal fuse and the thermistor in the same visit, and on one more the high limit thermal fuse. On more than one I cleaned the vent or told the owner it needed cleaning.
- Six of fifty-five — the gas valve coils had failed on a gas dryer. One of those needed the coils ordered and fitted on a return visit.
- Four of fifty-five — the thermal fuse. Two were blown, one had failed, and one was a failed high limit thermal fuse. That last machine also needed a cycling thermostat and a heating element. Another needed a wiring lead and a thermostat that was missing altogether.
- Four of fifty-five — the thermostats. Three were a failed cycling thermostat and one was a failed high limit thermostat. On most of these the cycling and high limit thermostats were replaced as a pair.
- Three of fifty-five — the vent. Two were clogged and I cleaned them out. The third was the E01 machine: the flap on the outside vent hood was stuck.
- Three of fifty-five — the timer. Two timers had failed outright. On the third, the heat switch on the timer had failed, along with a wire connector.
- Two of fifty-five — the terminal block where the power cord connects. One needed a new power cord along with it. The other needed a new vent transition and a terminal block cover.
- One each — a failed heater terminal; a failed drive motor and switch; worn drum rollers and belt, fixed with a repair kit; and a tripped breaker in the house panel.
Add it up. The heating parts themselves account for forty-four of fifty-five: the element, the gas valve coils, the thermal fuses, the thermostats and the heater terminal. Only four of fifty-five were something an owner could check without opening the dryer: the three vents and the one breaker.
What you can safely check first — and the honest odds
The breaker. An electric dryer runs on a double breaker. If only one half trips, the drum can keep turning while the heat is dead. Go to the panel, push the dryer breaker fully off, then back on. If it trips again, leave it off and call. A breaker that keeps tripping is not a reset problem. That fixed it once in fifty-five.
The vent. Clean the lint screen. Then go outside while the dryer is running and look at the vent hood. The flap should be open and you should feel a strong push of warm-ish air. A weak breath or a closed flap means the air is not getting out. That was three of fifty-five, including the one E01. If you want to look at the hose behind an electric dryer, unplug it first. On a gas dryer, do not move it at all; leave the hose behind it to me.
Do both. They cost nothing. But be realistic: four of fifty-five is the honest share these two checks will fix. If the breaker is fine and air is blowing hard outside, the odds say a heating part has failed.
What not to do: do not open the back or the front panel of an electric dryer while it is plugged in. Do not touch anything on a gas dryer beyond cleaning the lint screen. The terminal block where the cord enters the back is live wiring, and two of my fifty-five were failed terminal blocks. Leave that one alone. If you ever smell burning from a dryer, unplug it and do not run it again until it has been looked at.
The check that separates a one-part job from a three-part job
The trap on these dryers is the thermal fuse. It is cheap, it is easy to swap, and when it blows the heat stops. But a blown high limit fuse is often the result of something else, not the cause. It can blow because the dryer ran too hot, from a restricted vent or a cycling thermostat that was not doing its job. Swap the fuse alone and you can be back where you started after a few loads.
So the one thing that decides the job is measuring every part in the heat circuit, not just the first dead one I find. That means the element, the high limit, the cycling thermostat, the thermistor and the fuse. Then I check airflow at the outside hood before anything goes back together. That is why two of the element jobs above also got a new high limit thermal fuse and thermistor, a third got a fuse, and more than one came with a note about the vent. It is also why the thermal fuse jobs did not all stop at the fuse.
A couple of things worth telling me when you call:
- It is also noisy. One of these came in noisy as well as not heating, and it needed thermostats plus a belt, rollers and idler pulley kit. I would rather bring the right parts once.
- The drum is slow to start or sounds strained. On these dryers the motor’s switch has to close before the heat will come on, so a motor problem can look like a heat problem. One no-heat call was actually the drive motor and its switch.
- It is gas. A gas dryer has extra parts on the gas side, such as the valve coils. Six of mine needed gas valve coils. Anything on a gas dryer is a service call, never a weekend project.
What it costs
The service call is $167 ($187 for a stacked unit), a little more outside the regular route. It comes off the repair when you go ahead. You get a flat-rate quote before any work starts, and labor is covered for six months.
I have been fixing dryers in Stark County since 2018, and a Whirlpool that runs cold is about as routine as it gets. The parts are common. A dryer that will not heat is a repair, not a reason to replace it.
Breaker is on, the vent is blowing hard outside, and the Whirlpool is still running cold? Schedule online any time, or call or text (330) 693-9163.