GE Refrigerator Repair (Model PYE23KSDCSS) – Louisville, OH
In Louisville, OH, a warm refrigerator risks food spoilage and wasted energy. We quickly identified the fault so this Stark County home could keep food safe.
- Complaint: Runs but no cooling in fresh food or freezer.
- Cause: Failed inverter board preventing compressor start.
- Fix: Replaced inverter board; verified compressor operation.
- Result: Cooling restored in both compartments.
Diagnostic Findings
- 120 VAC present at converter
- 2.4 VDC signal to inverter board
- Compressor not operating
- Diagnosed failed inverter board
DIY? Read This First — Unplug the appliance and disconnect utilities before attempting repairs.
Disclosure: Some links below are affiliate (“sponsored”). We may earn a small commission.
Repairs Performed
Typical repair range: $231.49–$331.49.
If the repair cost approaches 50% of a new unit, it may be worth exploring replacement options.
Maintenance Tips for Appliances
- Clean condenser coils every 6–12 months.
- Keep door gaskets clean; replace if cracked or loose.
- Stark County humidity: leave space around vents for airflow.
- Avoid overloading; set 37°F fridge and 0°F freezer.
Final Verification
We completed functional tests to verify proper operation and checked for leaks, errors, and responsiveness.
Schedule service · Read reviews · Find parts