GE Dishwasher Repair (Model DDT595SMJ0ES) – Waynesburg, OH
Dishwasher powered on but wouldn’t start. Main control board had 120V but no response; replacing the control restored normal operation.
Dishwasher powered on but wouldn’t start. Main control board had 120V but no response; replacing the control restored normal operation.
The large burner on this GE range was heating poorly. Testing found the burner thermostat open; replacing the burner restored full, even heat.
A GE refrigerator in Canton, OH wasn’t maintaining proper temperatures — the fridge compartment wouldn’t go below 50 degrees. Our diagnosis revealed a failed fresh food recirculation fan and a plugged defrost drain that needed immediate attention. The Problem The customer reported that the temp in fridge won’t go below 50 degrees. This temperature issue … Read more
Washer lid would not lock and water dripped into the tub when off. Replaced a failed lid switch and a faulty water inlet valve to restore normal use.
GE dryer in Louisville, OH was loud while tumbling. Replaced worn front upper bearing assembly to restore quiet, smooth operation.
We responded to a service call in Canton, OH for a GE washer that wasn’t completing wash cycles. The machine was not draining or spinning, leaving clothes soaked at the end of what should have been a complete wash. Our diagnosis revealed a failed drain pump assembly that needed replacement. The Problem The customer reported … Read more
A Louisville homeowner contacted us when their GE dishwasher’s soap compartment stopped opening reliably during wash cycles. The spring mechanism was malfunctioning, leaving dishes with a cloudy residue that required re-rinsing and drying. The Problem The soap compartment would not open and release soap during a wash cycle. The spring seemed to malfunction most times … Read more
The GE dishwasher would not power on. Replacing the UI and main control boards restored operation; unit tests good.
The dishwasher wasn’t cleaning because the water supply valve was shut off. We opened the valve; it now fills, washes, and tests good.
A Hartville customer called about their GE dryer GTDP180GD0WW that wouldn’t heat after another repair company quoted over $600 and claimed a wiring harness wasn’t available. Our inspection revealed an open igniter, cracked drive belt, and failed gas valve coils — all repairable with standard parts. The Problem The customer reported no heat whatsoever from … Read more